What is the API 598 shell test multiplier?
Typically 1.5 times the cold working pressure (CWP) of the valve rating for hydrostatic shell testing, held for the duration required by the edition and size.
Updated 2026-11-10 · Screening tool for engineers & contractors · Verify against the current ASME / API / EN / IBR edition before design freeze.
Direct answer · What this calculator does
Got a size from this tool? Send type · size · Class/PN · MOC · ends · qty for a quote from Ahmedabad.
Contact / RFQ Quote page WhatsApp| ASME Class | Typical WCB CWP (bar g) ~ambient | Shell ≈1.5× (bar) | Seat ≈1.1× (bar) |
|---|---|---|---|
| 150 | 19.6 | 29.4 | 21.6 |
| 300 | 51.1 | 76.7 | 56.2 |
| 600 | 102.1 | 153.2 | 112.3 |
| 900 | 153.2 | 229.8 | 168.5 |
| 1500 | 255.3 | 383.0 | 280.8 |
Illustrative Group 1.1 ambient values for orientation. Always use the published B16.34 table for the exact material group.
Typically 1.5 times the cold working pressure (CWP) of the valve rating for hydrostatic shell testing, held for the duration required by the edition and size.
Hydrostatic seat tests are commonly 1.1 × CWP. Low-pressure air seat tests use a much lower pressure (often around 80–100 psig) when specified.
For process isolation valves yes, unless the purchaser names another standard (e.g. EN 12266, API 6D). Write the standard clearly on the PO.
Supreme Valves India supplies constructions by size, rating, MOC and ends. Calculator outputs are engineering screening aids, not a certified design deliverable.