API 598 Test Pressure Calculator — Shell & Seat by Class / PN

Updated 2026-11-10 · Screening tool for engineers & contractors · Verify against the current ASME / API / EN / IBR edition before design freeze.

Direct answer · What this calculator does

Enter cold working pressure (CWP) or pick ASME Class / PN. The calculator returns typical shell hydro ≈ 1.5× CWP and seat hydro ≈ 1.1× CWP, plus a common air seat ≈ 80–100 psig (≈ 5.5–7 bar) note for low-pressure closure checks.

Got a size from this tool? Send type · size · Class/PN · MOC · ends · qty for a quote from Ahmedabad.

Contact / RFQ Quote page WhatsApp

Inputs

Results

Copy these numbers into your RFQ, or open Contact / RFQ.

Formulas used

Shell P_shell ≈ 1.5 × CWP
Seat P_seat ≈ 1.1 × CWP
Air / low-pressure seat (typical practice): 80–100 psig (≈ 5.5–7 bar g) — confirm purchaser spec
CWP from Class: use ASME B16.34 Group 1.1 WCB room-temp rating as screening default
State on the PO: “Hydrostatic shell and seat tests per API 598. Provide test chart with gauge readings.” Add TPI / EN 10204 3.2 only if the purchaser pays for it.
Screening only. Exact CWP depends on material group and temperature. Freeze test pressures on the valve’s ASME B16.34 / EN rating plate and the purchaser specification — not this screening tool alone.

Reference table

ASME ClassTypical WCB CWP (bar g) ~ambientShell ≈1.5× (bar)Seat ≈1.1× (bar)
15019.629.421.6
30051.176.756.2
600102.1153.2112.3
900153.2229.8168.5
1500255.3383.0280.8

Illustrative Group 1.1 ambient values for orientation. Always use the published B16.34 table for the exact material group.

How to use the result on an RFQ

  1. Run the calculator with your design data.
  2. Record the key outputs shown in green.
  3. Paste type, size, Class/PN, MOC, ends and quantity into contact.html or WhatsApp.
  4. Ask for EN 10204 3.1 MTC and API 598 test notes when the purchaser requires them.

FAQ

What is the API 598 shell test multiplier?

Typically 1.5 times the cold working pressure (CWP) of the valve rating for hydrostatic shell testing, held for the duration required by the edition and size.

What is the seat test multiplier?

Hydrostatic seat tests are commonly 1.1 × CWP. Low-pressure air seat tests use a much lower pressure (often around 80–100 psig) when specified.

Should every RFQ demand API 598?

For process isolation valves yes, unless the purchaser names another standard (e.g. EN 12266, API 6D). Write the standard clearly on the PO.

Related calculators & charts

Supreme Valves India supplies constructions by size, rating, MOC and ends. Calculator outputs are engineering screening aids, not a certified design deliverable.