Duplex Valve RFQ Checklist: Tag List vs Vendor Drawing
Technical guide · Supreme Valves India · Updated 2026-11-17
Direct answer: When a duplex RFQ has both a tag list and a vendor drawing pack, quote the tag list + standards unless the buyer explicitly says “match the drawings.” Flag every conflict in writing before price commitment.
Conflicts that must stop the clock
- Tag size 25 NB vs drawing Size 40 globe
- Tag Class 600 vs drawing Class 800 ball
- Tag PN10 SW vs drawing Class 150 SW
- Tag double-acting 24 V DC vs drawing single-acting / 230 V AC
- Blank pressure-part MOC (e.g. bonnet empty) on a “Duplex” sheet
- Packing called asbestos on a modern duplex offer
- Wrong design standard (e.g. butterfly standard on a ball leaflet)
- Socket depth below ASME B16.11 minima
How Supreme handles it
We send a short clarification: quote basis (A) drawings as shared or (B) tag list + ASME/ISO/API/EN practice. Until the buyer picks A or B, delivery clocks and GA approval should not start.
Minimum duplex PO text
“Body/bonnet/trim UNS S32205 (or S31803 as agreed), ends and class per tag list, non-asbestos packing, design standard ____, test ____, EN 10204 3.1 MTC.”
Related pages: duplex manufacturer, F51 vs F53, RFQ.
Frequently asked questions
Should I approve a drawing that shows Size 40 when the tag is 25 NB?
No. Face-to-face and flange drilling will be wrong. Reject or revise before approval.
UNS S31803 or S32205?
Both are duplex families used commercially as 2205-type. Confirm the exact grade on the purchase order and MTC. Do not leave “Duplex” unqualified on critical chloride service.
Is BS 5159 valid for ball valves?
No. BS 5159 is a cast-iron butterfly standard. Ball valves should reference ISO 17292, API 608/6D practice, or ASME B16.34 as applicable.