Leakage Class VI vs API 598 Soft Seat on Ball Valves

Technical guide · Supreme Valves India · Updated 2026-11-17

Direct answer: For on–off ball valves, production seat tightness should normally reference API 598 (soft seat / resilient seat clauses as applicable). FCI 70-2 Class VI is a control valve leakage class. Putting “Leakage Class VI” on a quarter-turn on–off datasheet without control-valve context is often copy-paste — clarify before approval.

Use the right standard

RFQ wording

“On–off ball valve, soft seat, production test API 598 soft-seated closure, shell test per API 598.” Avoid orphan “Class VI” labels unless the instrument engineer truly wants FCI 70-2.

Related: API 598 seat failures, RFQ.

Frequently asked questions

Is Class VI better than API 598?

They are different systems. Class VI (FCI 70-2) is a control-valve seat leakage class. API 598 defines production tests for isolation valves including soft-seated closure tests. Pick the standard that matches valve function.

Can an on-off ball be tested to Class VI?

Some buyers ask for it as a tightness marketing term. Prefer API 598 soft-seat acceptance unless the valve is genuinely a control valve under FCI 70-2.

Related products & guides