Is Sch 40 the same as standard wall?
For many NPS sizes historically yes, but always use the numeric schedule wall from B36.10 for design.
Updated 2026-11-08 · Screening reference — confirm against the current ASME / API / EN edition before IFC.
Direct answer · Pipe schedule chart
| NPS | DN | OD (mm) | Sch 40 wall (mm) | Sch 80 wall (mm) |
|---|---|---|---|---|
| ½" | 15 | 21.3 | 2.77 | 3.73 |
| ¾" | 20 | 26.7 | 2.87 | 3.91 |
| 1" | 25 | 33.4 | 3.38 | 4.55 |
| 1½" | 40 | 48.3 | 3.68 | 5.08 |
| 2" | 50 | 60.3 | 3.91 | 5.54 |
| 3" | 80 | 88.9 | 5.49 | 7.62 |
| 4" | 100 | 114.3 | 6.02 | 8.56 |
| 6" | 150 | 168.3 | 7.11 | 10.97 |
| 8" | 200 | 219.1 | 8.18 | 12.70 |
| 10" | 250 | 273.1 | 9.27 | 12.70 |
| 12" | 300 | 323.9 | 9.53 | 12.70 |
| 14" | 350 | 355.6 | 9.53 | 12.70 |
| 16" | 400 | 406.4 | 9.53 | 12.70 |
| 18" | 450 | 457.2 | 9.53 | 12.70 |
| 20" | 500 | 508.0 | 9.53 | 12.70 |
| 24" | 600 | 610.0 | 9.53 | 14.27 |
Stainless schedules (e.g. Sch 10S/40S) differ — do not mix carbon and stainless schedule tables. ID = OD − 2×wall (approx).
Buttweld valves are ordered to match pipe schedule (e.g. BW Sch 40). Flanged valves care more about flange class than schedule, but branch velocity and Cv sizing still use ID from the schedule chart.
| End type | Schedule note on RFQ |
|---|---|
| Flanged RF/RTJ | Schedule optional unless bore match required |
| Buttweld (BW) | Mandatory — Sch 40 / 80 / XS / XXS |
| Socket weld / NPT | Usually ≤2"; schedule still affects coupling |
For many NPS sizes historically yes, but always use the numeric schedule wall from B36.10 for design.
No. Schedule is pipe wall; Class/PN is flange/valve rating. Both must be specified.
See also pipe-schedule-table.html in this folder for the interactive/legacy view.