Saturated Steam Pressure-Temperature Chart for Globe & Gate Valve Sizing

Updated 2026-11-08 · Rounded steam-table screening values. Verify against your project steam tables / ASME steam properties before heat balances.

Direct answer · Saturated steam P-T

On the saturation curve, pressure fixes temperature (and vice versa). Example screens: 1 kg/cm²g ≈ 120 °C, 7 kg/cm²g ≈ 170 °C, 10 kg/cm²g ≈ 184 °C, 40 kg/cm²g ≈ 252 °C. Use Tsat to pick packing/MOC and Class rating; use density / specific volume for steam Cv. Superheat is a different design temperature.

Steam valve RFQ — size · Class · MOC · ends · design P/T · sat/superheat · qty.

Contact / RFQ WhatsApp

Contractors and plant engineers open a saturated steam P-T chart when converting nameplate boiler pressure into expected line temperature, when checking whether Class 150 still has margin at temperature, and when estimating steam density for globe-valve Cv. The tables below are dense enough for daily desk use; they remain screening data, not a certified steam table extract.

Saturated steam P-T table (gauge) — LP to HP

P (kg/cm²g)P ≈ (bar g)Tsat ≈ (°C)Tsat ≈ (°F)Typical plant use
0.50.5112234Very LP utility
1.01.0120248LP process / HVAC steam
1.51.5128262LP distribution
2.02.0134273LP process
2.52.5139282LP process
3.02.9143290LP header
3.53.4148298Common Indian LP
4.03.9152305LP / MP boundary
5.04.9159318MP light
6.05.9165329MP light
7.06.9170338Very common plant steam
8.07.8175347MP process
9.08.8180355MP process
109.8184363MP header
1211.8192377MP header
1413.7198388MP / HP light
1615.7204399MP steam
17.517.2207405Classic Indian MP
2019.6214417MP / HP
2120.6216421HP light
2524.5226439HP process
3029.4235455HP process
3534.3244471HP
4039.2252485HP boiler / power
5049.0265509HP
6058.8277530HP
6462.8281538HP Class 600 region
8078.5296565Power / HP
10098.1311592Power / HP

Values rounded for desk screening. Absolute pressure = gauge + local atmospheric (~1.033 kg/cm² at sea level). Correct for altitude on vacuum / LP condenser work.

Density / specific volume screen (for steam Cv)

Steam mass flow (kg/h) converts to volumetric flow using specific volume v (m³/kg) or density ρ = 1/v. Use inlet conditions for capacity; check critical pressure ratio for choked flow.

P (kg/cm²g)Tsat ≈ (°C)ρ steam ≈ (kg/m³)v ≈ (m³/kg)hf ≈ (kJ/kg)hfg ≈ (kJ/kg)
1120~1.1~0.88~505~2200
3.5148~2.4~0.42~625~2110
7170~4.1~0.24~720~2050
10184~5.5~0.18~780~2000
17.5207~8.8~0.11~880~1920
25226~12~0.083~960~1850
40252~18~0.055~1090~1710
64281~28~0.036~1230~1540
100311~43~0.023~1400~1320

Enthalpy and density figures are approximate mid-range values for orientation. Latent heat hfg falls as pressure rises — important for trap condensate load estimates.

How engineers use this chart with valves

TaskTake from chartThen open
Isolation Class pickTsat at design PIBR steam rating / B16.34 chart
Globe Cv estimateρ or v at inletValve Cv table + steam formula
Trap selectionΔT vs ambient / loadSteam trap selection chart
Packing / gasketTsat or TsuperheatGasket / trim charts
Blowdown flashBoiler P → flash TBlowdown valve chart

Vacuum / condenser side (absolute) — quick screen

P absolute (bar a)≈ mmHg vacuum (sea level)Tsat ≈ (°C)Note
0.05~725~33Deep condenser vacuum
0.10~685~46Condenser / LP turbine exhaust region
0.20~610~60Warm vacuum
0.50~385~81Deaerator / LP heater region depends on plant
1.0130 (atm)100Atmospheric boiling

Condensate and vacuum drain valves see low absolute pressure but can still see high temperature during air-inleak or startup. State vacuum service and design temperature separately on the RFQ.

Unit conversion reminders for steam RFQs

FromToFactor (approx.)
1 kg/cm²bar× 0.981
1 kg/cm²kPa× 98.1
1 kg/cm²psi× 14.22
1 barkPa× 100
°C°F× 1.8 + 32
Gauge → absolute—+ local atm (~1.033 kg/cm²)

FAQ

What is the temperature of saturated steam at 7 kg/cm²g?

Approximately 170 °C (rounded). Use the table on this page for nearby pressures and confirm exact Tsat from your project steam tables before heat-balance or Class selection.

How do I use this chart for globe valve sizing?

Convert steam mass flow to volumetric flow using specific volume (or density) at the inlet P-T, then apply the steam Cv equation from the purchaser standard. Check outlet pressure for critical drop and noise. Pair with the Cv chart and Class P-T rating.

Does superheated steam use the same temperature as saturation?

No. Superheat raises temperature above Tsat at the same pressure. Valve MOC and packing must follow the higher design temperature, not the saturation temperature alone.

Are kg/cm²g and bar interchangeable for plant steam?

1 kg/cm² ≈ 0.981 bar ≈ 98.1 kPa. Many Indian datasheets still use kg/cm²g. Convert carefully when mixing SI (bar/MPa) flange tables with older boiler nameplates.

Can Supreme Valves quote steam isolation valves from this chart?

Yes. Send size, Class/PN, MOC, ends, design P, design T (sat or superheat), IBR if applicable, and quantity via contact.html.

Related charts

Screening properties for 2026 engineering use. Confirm critical energy balances against project-approved steam tables and current ASME/IBR editions.