IBR Steam Valve Rating Chart — Temperature-Pressure Table for Indian Boiler Lines

Updated 2026-11-08 · Screening reference. Verify design pressure/temperature against current IBR, ASME B16.34 and purchaser datasheets before design freeze.

Direct answer · IBR steam valve rating

For Indian IBR steam lines, pick valve Class/PN so the ASME B16.34 (or EN) allowable at design °C is ≥ design pressure with purchaser margin. Typical plant practice: ≤7–10 kg/cm² sat steam → Class 150 / PN16 (often upgraded), ~16–25 kg/cm² → Class 300 / PN40, ~40–64 kg/cm² → Class 600 / PN63–100. Add IBR stamp, WCB/alloy MOC and RF/BW ends on the RFQ. This page is orientation only — not a substitute for the stamped design calculation.

IBR steam RFQ — size · Class/PN · MOC · ends · design P/T · IBR stamp · qty.

Contact / RFQ WhatsApp

Steam valve rating mistakes on IBR systems usually come from using ambient Class numbers without checking the pressure drop of allowable stress at temperature, or from omitting IBR form / stamp language on the purchase order. Use the tables below to screen Class and MOC, then lock values to the consulting engineer’s line list and the current editions of IBR and ASME B16.34 / B16.5 / B16.10.

Saturated steam P-T vs typical valve Class (screening)

Approximate saturated-steam gauge pressures and boiling temperatures are shown against common Indian plant Class/PN picks. Superheated steam needs separate design temperature — do not use saturation temperature alone.

Approx. P (kg/cm²g)Approx. Tsat (°C)Common Class screenCommon PN screenNotes for IBR lines
1.0~120150PN16Utility / LP process steam
3.5~148150PN16LP header; confirm B16.34 at T
7.0~170150 / 300PN16 / PN40Many specs jump to Class 300
10~184150 / 300PN16 / PN40Check WCB allowable at ~180 °C
14~198300PN40Typical MP process steam
17.5~207300PN40MP header / distribution
21~216300PN40Margin vs B16.34 critical
25~226300 / 600PN40 / PN63Purchaser-dependent upgrade
40~252600PN63 / PN100HP steam; alloy MOC often
64~281600 / 900PN100Confirm metallurgy + ends
100~311900 / 1500SpecialPower / HP boiler — OEM scope

Disclaimer: P-Tsat pairs are rounded engineering approximations for screening. Verify against steam tables and the design basis. Class/PN picks are industry practice examples, not mandatory IBR table values.

ASME Class vs EN PN — steam flange pairing

ASME ClassApprox. EN PN peerFlange face (steam)Typical ends on RFQ
150PN16 / PN20RF raised faceFlanged RF; SW ≤2" utility
300PN40 / PN50RF (RTJ if specified)Flanged RF / BW on large HP
600PN63 / PN100RF or RTJOften BW on critical HP
900PN150 regionRTJ commonBW preferred on mains
1500SpecialRTJ / BWPower plant / HP boiler

PN and Class are not identical allowable curves. Never mix PN16 flanges with Class 300 valves without an approved mismatch study. Match gasket, bolt and face finish to the line class list.

Body / trim MOC for IBR steam service

Service bandBody (cast)Typical trimStem / packing notes
LP sat steam ≤~180 °CWCB (A216)13Cr / SS304Graphite packing common
MP sat steam ~180–250 °CWCB / WC613Cr / SS410 / Stellite seat optionLive-load packing if cycling
HP / alloy steamWC6 / WC9 / C12AStellite / 17-4 / OEM trimPer metallurgy schedule
Condensate / drainWCB / CF8SS304 / SS316Globe preferred for throttling
Feedwater (non-IBR piping may vary)WCB / WC6SS trimCheck oxygen / chemistry

Forged A105 / F11 / F22 constructions appear on small SW/NPT drain and instrument take-offs. State forged vs cast explicitly.

Valve type roles on IBR steam headers

FunctionPreferred typeWhyAvoid / caution
Header isolationGate (OS&Y) or parallel-slideLow ΔP when openDo not throttle on gate
Throttling / startupGlobe (T / Y pattern)Controllable CvSize for noise / velocity
Non-returnSwing / piston / dual-plate checkStop reverse flowSlam risk — dampers if needed
Steam drainGlobe + trap trainThrottling + condensateSee steam trap chart
BlowdownAngle / specially rated BDVErosion / flashingSee blowdown chart
Safety reliefPSV per IBR / OEMOverpressure protectionOutside isolation-valve scope

Documentation typically requested with IBR steam valves

DocumentWhen askedRFQ note
IBR certificate / form referencesRegulated steam scopeState “IBR stamp required”
EN 10204 3.1 MTCAlmost always on EPC jobsBody + trim heats
API 598 / hydrotest chartFAT / inspectionWitness if ITP says so
GA drawing + BOMApproval cycleFace-to-face standard
Paint / heat number mapCritical HPMatch site coating Spec

Worked screening examples

Line descriptionDesign snapshotScreened valveRFQ one-liner
Process LP steam to dryer7 kg/cm²g sat, DN80Gate Class 150 WCB RFDN80 Class 150 WCB gate RF IBR, qty
MP steam distribution17 kg/cm²g sat, DN100Gate Class 300 WCB RFDN100 Class 300 WCB OS&Y RF IBR
HP steam drain40 kg/cm²g, DN25Globe Class 600 forged SWDN25 Class 600 A105 globe SW IBR
Boiler main stop (plant specific)Per OEMPer boiler OEM / IBRDo not substitute from this chart alone

Main steam stop / non-return valves on the boiler itself are usually OEM or specially approved constructions. Use this chart for plant steam distribution, utility headers, drains and process take-offs unless the boiler inspector directs otherwise.

FAQ

When does IBR apply to steam valves in India?

IBR (Indian Boiler Regulations) covers steam boilers and connected steam piping under the regulated pressure/temperature scope of the Act. Isolation and drain valves on IBR steam lines typically require IBR certification / form stamping as specified by the boiler inspector and purchaser. Confirm scope on the P&ID and the consulting engineer’s datasheet.

Is Class 150 enough for 10 kg/cm² saturated steam?

Saturated steam at about 10 kg/cm²g is roughly 180 °C. Class 150 WCB allowable pressure falls with temperature per ASME B16.34; many Indian plants still use Class 150 / PN16 on low-pressure steam, but the purchaser often upgrades to Class 300 / PN40 for margin, cycling and inspector preference. Screen against the current B16.34 / EN 1092 P-T table and the IBR design pressure.

What MOC is typical for IBR steam gate and globe valves?

Low-to-medium pressure saturated steam commonly uses ASTM A216 WCB body with 13Cr / SS304 trim. Higher temperature or alloy steam may need WC6 / WC9 / C12A and upgraded stem/seat materials. State design P, design T, fluid (sat / superheat), and IBR stamp requirement on the RFQ.

Do IBR steam valves need API 598 testing?

Factory shell and seat hydrotests are normally performed to API 598 or equivalent purchaser specs, plus any IBR witness / form requirements. Hold times and acceptance criteria follow the order datasheet — not this screening chart alone.

What RFQ fields are needed for IBR steam valves?

Size (DN/NPS), Class or PN, body MOC, trim, ends (RF/RTJ/BW/SW), design pressure and temperature, saturated or superheated, IBR stamp yes/no, quantity, and any drain/bypass package.

Related charts