Valve Equivalent Length Calculator — K-Factor & L/D

Updated 2026-11-10 · Screening tool · Verify against current standards before design freeze.

Direct answer · What this calculator does

Each valve adds a resistance K. Equivalent length L_eq ≈ K × D / f (or published L/D × D). Use this to budget ΔP before pumps and control valves.

Got a size from this tool? Send type · size · Class/PN · MOC · ends · qty.

Contact / RFQ Quote page WhatsApp

Valve resistance inputs

m/s
kg/m³

Results

Copy into your RFQ or open Contact / RFQ.

Formulas used

ΔP = K × ρ × V² / 2
L_eq ≈ (L/D) × D  with typical fully-open L/D:
Gate ≈ 8 · Ball (full bore) ≈ 3 · Butterfly ≈ 20 · Swing check ≈ 100 · Globe ≈ 300
K ≈ f × (L/D) with f≈0.02 screening for turbulent steel pipe
Globe valves dominate ΔP — correct for throttling, poor for pump suction. Prefer full-bore ball / gate for isolation with low loss.
Screening only. Manufacturer Cv is more accurate than generic K. Convert Cv to K when a tested Cv is available: K ≈ 891 d⁴ / Cv² (d in inches, US customary screening).

Reference table

Type (full open)Typical L/DUse
Full-bore ball~3Low-loss isolation
Gate~8Isolation
Butterfly~20Utility isolation / modulation
Swing check~50–150Backflow
Globe~300Throttling

How to use the result on an RFQ

  1. Run with your design data.
  2. Record the green outputs.
  3. Paste type, size, Class/PN, MOC, ends, qty into contact or WhatsApp.
  4. Request 3.1 MTC / API 598 notes when required.

FAQ

Should I use K or Cv?

Procurement RFQs usually state size/class/Cv. Hydraulics often use K or equivalent length. Either works if converted consistently.

Does a reduced-bore ball change K?

Yes — higher K / lower Cv. State full bore vs reduced bore on the RFQ.

Where do check valves sit in the budget?

Swing checks can add significant loss; dual-plate often lower — confirm manufacturer data.

Related calculators & charts

Supreme Valves India supplies constructions by size, rating, MOC and ends. Outputs are screening aids, not certified design.