Ul Fm Alarm Valve

UL Listed FM Approved NFPA 13/20 Compliant

UL Listed and FM Approved ul fm alarm valve for fire protection systems. Designed per NFPA standards for commercial and industrial fire suppression applications.

Product Overview

UL Listed and FM Approved ul fm alarm valve for fire protection systems. Designed per NFPA standards for commercial and industrial fire suppression applications.

Request Quote WhatsApp

Certifications

  • UL Listed (UL 508)
  • FM Approved (FM 1120/1130)
  • NFPA 13 / NFPA 20 Compliant
  • SABER Compliant (Saudi Arabia)
  • Civil Defence Approved (UAE)

Technical Specifications

TypeUL FM Approved Valve
StandardUL 508 / FM 1120
Size Range0.5" - 24" (DN15 - DN600)
Pressure RatingClass 150 / 300 (PN20/PN50)
ConnectionThreaded / Flanged / Grooved
Body MaterialCast Iron / Ductile Iron / Carbon Steel
OperatorHandwheel / Lever / Gear / Actuator

Key Features

Export to Middle East & Global Markets

Supreme Valves is a leading exporter of UL FM approved fire protection valves from India to Saudi Arabia, UAE, Qatar, Kuwait, Bahrain, and Oman. All valves are shipped with complete documentation including material test certificates (MTC), factory inspection reports, and certificates of origin for customs clearance. SABER PC compliance support available.

Applications

  • Commercial building fire sprinkler systems
  • Industrial plant fire suppression
  • Oil and gas facility fire protection
  • Data center fire suppression
  • Warehouse and logistics center fire systems
  • Healthcare facility fire protection
  • Power plant fire suppression
  • Marine and offshore platform fire systems
  • Frequently Asked Questions

    What is UL and FM certification for fire protection valves?

    UL (Underwriters Laboratories) and FM (Factory Mutual) certifications verify that fire protection equipment meets rigorous safety and performance standards tested by independent laboratories. UL 508 covers electrical safety for control valves, while FM 1120/1130 covers the performance of fire protection valves including pressure, temperature, and fire-safe ratings. These certifications are required by building codes in Saudi Arabia, UAE, and Qatar for fire suppression systems in commercial and industrial facilities, and FM approval can lead to reduced insurance premiums.

    What fire protection standards apply to these valves in the Middle East?

    In Saudi Arabia, UAE, Qatar, and other GCC countries, fire protection valve specifications typically reference NFPA (National Fire Protection Association) standards adopted by Gulf Cooperation Council (GCC) standardization bodies. Key standards include NFPA 13 (sprinkler systems), NFPA 14 (standpipes), NFPA 20 (fire pumps), NFPA 24 (underground piping), and NFPA 72 (alarm systems). SABER compliance is required for product entry into Saudi Arabia, and our UL FM certified valves come with complete documentation packages for SABER PC (Product Certificate) registration.

    What maintenance is required for UL FM approved fire valves?

    NFPA 25 (Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems) mandates regular inspection and testing intervals for fire protection valves. Main isolation valves require weekly visual inspection of position indicators and monthly documentation of stem lubrication. Annual partial operational tests (opening and closing) are required. Supreme Valves provides maintenance manuals with every fire protection valve, including stem lubrication schedules, packing replacement procedures, and seat inspection criteria per API 600 and manufacturer recommendations.

    What is the lead time for UL FM certified valves from India?

    Standard UL FM approved fire protection valves ship within 3-5 weeks from our Ahmedabad manufacturing facility. For large quantities or custom configurations (specialized actuators, extended stems, custom flange drilling), lead times extend to 6-8 weeks. Air freight options are available for urgent requirements in Saudi Arabia, UAE, and Qatar. Supreme Valves handles all export documentation including bill of lading, certificate of origin (Form A or CO), and inspection certificates (SGS or Bureau Veritas) upon request.

    How do I select the correct fire protection valve for my application?

    Valve selection for fire protection is determined by system type (wet pipe, dry pipe, preaction, deluge), design pressure, temperature range, and connection type. NFPA 13 and system designer specifications govern the valve type and rating. As a general guideline: butterfly valves are preferred for zone isolation in large commercial buildings, gate valves for fire pump installations per NFPA 20, check valves at fire pump discharges, and ball valves for system isolation points. Our technical team can review your bill of materials (BOM) and recommend the correct valve specification for your NFPA-compliant system.

    Ready to Order?

    Contact our export team for pricing, lead times, and technical support for your fire protection project.

    Request Quotation WhatsApp: +91 97732 78770

    Email: supremevalvesindia@gmail.com | We export to Saudi Arabia, UAE, Qatar, Kuwait, Oman, Bahrain