ISO 5211 Actuator Flange Selector — Torque → Flange Pattern

Updated 2026-11-10 · Screening tool · Verify against current standards before design freeze.

Direct answer · What this calculator does

Enter breakaway / run torque. The tool suggests a minimum ISO 5211 flange band and reminds you to apply a safety factor (often 1.25–2.0×) before buying the actuator.

Got a size from this tool? Send type · size · Class/PN · MOC · ends · qty.

Contact / RFQ Quote page WhatsApp

Torque inputs

Nm

Results

Copy into your RFQ or open Contact / RFQ.

Formulas used

Select actuator rated torque ≥ SF × valve torque
Typical SF: clean service 1.25–1.5 · sticky / dry 1.5–2.0 · safety critical higher
Flange screening by torque band (Nm): F05 ≤125 · F07 ≤250 · F10 ≤500 · F12 ≤1000 · F14 ≤2000 (order-of-magnitude — confirm ISO 5211 table / OEM)
Always size on breakaway torque at max ΔP, not mid-stroke running torque. State air supply bar for pneumatic, voltage for electric.
Screening only. ISO 5211 defines interfaces, not the exact actuator model. OEM torque charts and stem dimensions govern the final pick.

Reference table

FlangeScreening torque bandCommon drive squares
F05≤ ~125 Nm14 / 17 mm
F07≤ ~250 Nm17 / 22 mm
F10≤ ~500 Nm22 / 27 mm
F12≤ ~1000 Nm27 / 36 mm
F14≤ ~2000 Nm36 / 46 mm

How to use the result on an RFQ

  1. Run with your design data.
  2. Record the green outputs.
  3. Paste type, size, Class/PN, MOC, ends, qty into contact or WhatsApp.
  4. Request 3.1 MTC / API 598 notes when required.

FAQ

Breakaway vs running torque?

Breakaway (unseat) is usually highest — size the actuator on that at maximum differential pressure.

Do I need a gear box?

Large manual valves often need bevel / worm gears. Actuated packages may still use gears between stem and actuator.

DA vs spring-return?

Double-acting needs air to open and close. Spring-return fails open or closed on air loss — specify the fail position.

Related calculators & charts

Supreme Valves India supplies constructions by size, rating, MOC and ends. Outputs are screening aids, not certified design.