Liquid PSV Orifice Area Calculator — API 520 Screening

Updated 2026-11-10 · Screening tool · Verify against current standards before design freeze.

Direct answer · What this calculator does

Liquid relief screening: A ≈ (Q / (Kd × Ku × Kw × Kc)) × √(G / ΔP) style forms. This tool gives a first-cut area so you can discuss orifice letter and valve inlet size — final stamp sizing is by the PSV OEM.

Got a size from this tool? Send type · size · Class/PN · MOC · ends · qty.

Contact / RFQ Quote page WhatsApp

Liquid relief inputs

US gpm
psig
psig

Results

Copy into your RFQ or open Contact / RFQ.

Formulas used

Screening (US gpm, psi, in²): A ≈ 0.3208 × Q × √(G/ΔP) / (Kd×other K≈0.65 default bundle)
Implemented as A_in2 = (Q × √(G/ΔP)) / (38 × Kd_eff)
ΔP = set − backpressure (psi)
State set pressure, overpressure %, backpressure and fluid on every PSV RFQ.
Screening only. Not certified sizing. Fire case, two-phase and steam use different API 520 methods.

Reference table

LetterArea in² (API)
D0.110
E0.196
F0.307
G0.503
H0.785
J1.287

How to use the result on an RFQ

  1. Run with your design data.
  2. Record the green outputs.
  3. Paste type, size, Class/PN, MOC, ends, qty into contact or WhatsApp.
  4. Request 3.1 MTC / API 598 notes when required.

FAQ

What Kd should I use?

Certified Kd comes from the valve. 0.65 is a conservative liquid screening placeholder.

PRV vs PSV wording?

Plant language varies. On RFQs say “pressure relief / safety valve” plus set pressure and code.

Do you stamp PSV?

Sizing/stamping follows OEM and local code. We can supply associated block valves and discuss package scope.

Related calculators & charts

Supreme Valves India supplies constructions by size, rating, MOC and ends. Outputs are screening aids, not certified design.