Steam Mass Flow Cv Calculator — Saturated Steam Screening

Updated 2026-11-10 · Screening tool for engineers & contractors · Verify against the current ASME / API / EN / IBR edition before design freeze.

Direct answer · What this calculator does

For dry saturated steam screening: Cv ≈ W / (2.1 × √(ΔP × (P1 + P2))) with W in kg/h and pressures in bar a (common simplified form). Enter mass flow, inlet pressure and ΔP to size a globe / control valve starting point, then confirm with manufacturer steam Cv curves.

Got a size from this tool? Send type · size · Class/PN · MOC · ends · qty for a quote from Ahmedabad.

Contact / RFQ Quote page WhatsApp

Steam inputs

kg/h
bar g → converted to bar a (+1.013)
bar

Results

Copy these numbers into your RFQ, or open Contact / RFQ.

Formulas used

Simplified saturated steam (metric screening):
Cv ≈ W / (2.1 × √(ΔP × (P1 + P2)))
W = kg/h, P1/P2/ΔP in bar a, P2 = P1 − ΔP
Imperial alternate often seen: Cv = W_lb/h / (63.3 × √(ΔP_psi × γ)) with density term
Rule of thumb: keep ΔP ≤ 0.3–0.5 × P1 for non-critical steam throttling unless anti-cavitation / noise trim is specified
Prefer globe or characterised control valves for steam throttling. Gate valves are for isolation only — do not throttle on a gate.
Screening only. Real steam sizing needs dryness fraction, superheat, noise, velocity and IEC/ISA compressible equations. This tool is a first-cut Cv only.

Reference table

Typical lineStarting valve typeNotes
Boiler stop / isolationGate or parallel-slideFull bore, IBR docs when required
Steam throttling / PRV upstreamGlobe / controlUse this Cv as starting point
Continuous blowdownGlobe / angleErosion trim; see blowdown calculator
Drain / trap station isolationGate / pistonMatch P-T class to steam table

How to use the result on an RFQ

  1. Run the calculator with your design data.
  2. Record the key outputs shown in green.
  3. Paste type, size, Class/PN, MOC, ends and quantity into contact.html or WhatsApp.
  4. Ask for EN 10204 3.1 MTC and API 598 test notes when the purchaser requires them.

FAQ

Can I use liquid Cv formulas for steam?

No. Steam is compressible. Use steam / gas equations or manufacturer steam Cv charts.

What ΔP should I assume?

Use the actual available pressure drop from the P&ID. If unknown, start with 10–30% of absolute inlet pressure and iterate with process.

Do IBR valves need a different Cv?

IBR is a documentation / statutory path. Cv still comes from the steam duty — then select an IBR-documented construction.

Related calculators & charts

Supreme Valves India supplies constructions by size, rating, MOC and ends. Calculator outputs are engineering screening aids, not a certified design deliverable.