WCB Swing Check Valve
ASTM A216 Grade WCB swing check (NRV) — full-bore, low pressure drop for pump discharge, steam, water and process lines. Class 150–600 RF flanged. Also available in CF8 / CF8M and NAB. See the WCB swing check manufacturer page and WCB ball vs gate vs globe vs swing check guide.
Key Applications
Technical Specifications
Material of Construction
Body, trim and seat materials are selected for the service conditions and confirmed on the quotation and datasheet. State the fluid, pressure and temperature with your enquiry.
Selection guide
A swing check valve prevents reverse flow with a hinged disc that swings open with forward flow and closes under gravity and back pressure. It has a nearly full bore and low pressure drop, which makes it the default non-return valve on pump discharge, water and steam lines with steady flow.
Choosing a check valve type
- Swing check: low pressure drop, simple, suits horizontal lines and vertical lines with upward flow. Can slam where flow reverses quickly.
- Dual plate (wafer) check: two spring-loaded half discs, short face-to-face and fast closing. Good for limited space and for reducing water hammer.
- Lift check: disc lifts vertically off the seat; suits small bore and high pressure, often forged.
- Non-slam (nozzle) check: spring-assisted, very short stroke; used on pump stations and compressor discharge where slam and surge must be minimised.
Installation points
Install with the flow arrow in the flow direction, in horizontal lines or vertical lines with upward flow only. Allow straight pipe upstream (commonly five pipe diameters or more) after pumps, elbows and reducers, so the disc doesn't flutter. Oversized check valves that never open fully wear the hinge pin and disc.
Standards
BS 1868 and ASME B16.34 for flanged swing check valves, API 594 for wafer, lug and double flanged check valves including dual plate, API 6D for pipeline service, API 602 for small forged check valves. Testing to API 598.
Check valve manufacturer India: types →
Frequently asked questions
Why does a swing check valve slam?
Slam happens when flow reverses before the disc has closed, typically when a pump trips. The reverse flow then slams the disc onto the seat and causes a pressure surge. A spring-assisted dual plate or non-slam check valve closes faster and reduces slam.
Can a swing check valve be installed vertically?
Only with flow going upward, so gravity helps close the disc. It must not be installed with downward flow, because the disc would hang open.
Purchase Options
Features & Benefits
High Performance
Designed for reliable operation under demanding conditions with minimal maintenance requirements.
Quality Assurance
Complete material traceability, mill test certificates, and compliance with international standards.
Wide Application Range
Suitable for Pump Discharge, Pipeline, Water Systems and many other industrial applications.
Expert Support
Technical assistance for valve selection, sizing, and application engineering from our experienced team.
Request a Quote
Your enquiry is pre-filled with this specification. Add contact details and quantity and our engineering team responds within one working day with price and delivery.
Prefer to talk first? WhatsApp or email info@supremevalves.in