Is WCB acceptable for cryogenic service?
No for true cryogenic / impact-tested low-temperature service. Use LCB/LCC or austenitic stainless (CF8M/CF3M) per design minimum temperature.
Updated 2026-11-08 · Screening reference for engineers & contractors.
Direct answer · Cryogenic / LT MOC
| Grade | Standard | Typical MDMT screening | Where used | Notes |
|---|---|---|---|---|
| WCB | A216 | ≈ −29 °C | Ambient CS process | Not for cryogenic / −46 °C lists |
| LCB | A352 | ≈ −46 °C | LT hydrocarbon | Impact tested LTCS casting |
| LCC | A352 | ≈ −46 °C | Preferred LTCS on many MTOs | Higher strength than LCB |
| LF2 (forged) | A350 | ≈ −46 °C | Forged LT valves / flanges | Counterpart to LCB/LCC castings |
| CF8 / CF8M | A351 | Cryogenic (austenitic) | LNG, LIN, LOX*, cold boxes | Excellent toughness at low T |
| CF3 / CF3M | A351 | Cryogenic | Welded / low-carbon preference | Often specified with BW ends |
| F316 / F316L | A182 | Cryogenic | Forged cryo ball / needle | Match casting/forging design |
*Oxygen service needs cleaning, grease-free assembly and purchaser oxygen-compatibility rules — state “oxygen service” explicitly on the RFQ.
| Service temperature band | Typical body start | Escalate when |
|---|---|---|
| Above −29 °C | WCB / A105 | Corrosion needs SS |
| −29 to −46 °C | LCB / LCC / LF2 | Purchaser demands stainless |
| Below −46 °C (e.g. LNG ≈ −162 °C) | CF8M / CF3M / F316L | Special alloys per owner spec |
| Liquid nitrogen / argon | Austenitic SS | Extended bonnet + seat notes |
| Liquid oxygen | SS + O₂ cleaning package | Owner oxygen procedure mandatory |
| Feature | Why it matters | Write on RFQ |
|---|---|---|
| Extended bonnet / gas column | Keeps packing away from cold fluid | “Cryogenic extended bonnet” |
| Seat material | PTFE / PCTFE / metal per temp | Soft seat grade or metal seat |
| Stem / anti-blowout | Safety at cold operation | API / BS cryo design notes |
| Body cavity relief | Trapped liquid expansion | Cavity relief / DIB notes if required |
| Low-temp seat test | Leakage at MDMT | Test media & temperature |
| Impact test / MTC | Proves toughness | EN 10204 3.1 + impact at MDMT |
| LCB | LCC | CF8M | |
|---|---|---|---|
| Family | LT carbon cast | LT carbon cast | 316 SS cast |
| Cost | Lower | Lower–mid | Higher |
| Typical MDMT | −46 °C | −46 °C | Cryogenic |
| Corrosion | Like CS | Like CS | Better chemical resistance |
| LNG liquid | Usually no | Usually no | Yes (with cryo design) |
Screening disclaimer: MDMT values above are typical industry orientation. Final material and design temperature must follow ASME B31.3 / purchaser minimum design metal temperature, impact test exemption curves and the approved datasheet. Soft-seat temperature limits can govern before body MOC does.
| Field | Example / why |
|---|---|
| Minimum design metal temperature (MDMT) | −46 °C / −162 °C / … |
| Media | LNG / LIN / LOX / LT hydrocarbon |
| Body MOC preference | LCC / CF8M / F316L |
| Valve type · size · Class · ends | Ball / globe / gate; BW often on cryo |
| Extended bonnet required? | Yes / No + length if specified |
| Seat / soft parts | PCTFE / PTFE / metal |
| Testing package | API 598 + low-temp seat test notes |
| Oxygen cleaning? | Only if O₂ service |
| Quantity · delivery | Commercial offer |
No for true cryogenic / impact-tested low-temperature service. Use LCB/LCC or austenitic stainless (CF8M/CF3M) per design minimum temperature.
LNG cold boxes and liquid lines typically use austenitic stainless. LCB/LCC cover many low-temperature hydrocarbon duties around −46 °C, not full LNG liquid temperatures.
Minimum design temperature, media, size, Class, ends, extended bonnet requirement, seat material, testing (including low-temp seat test if specified) and quantity via contact.html.