Cryogenic Valve Material Chart

Updated 2026-11-08 · Screening reference for engineers & contractors.

Direct answer · Cryogenic / LT MOC

For low-temperature and cryogenic valves, do not default to WCB. Use ASTM A352 LCB / LCC for many impact-tested hydrocarbon duties near −46 °C, and CF8M / CF3M (or forged F316/F316L) for colder LNG / LIN / LOX service. Extended bonnets, seat materials and low-temperature testing belong on the RFQ.

RFQ cryogenic valves — MDMT · media · size · class · ends · bonnet · qty.

Contact / RFQ WhatsApp

Body material orientation

GradeStandardTypical MDMT screeningWhere usedNotes
WCBA216≈ −29 °CAmbient CS processNot for cryogenic / −46 °C lists
LCBA352≈ −46 °CLT hydrocarbonImpact tested LTCS casting
LCCA352≈ −46 °CPreferred LTCS on many MTOsHigher strength than LCB
LF2 (forged)A350≈ −46 °CForged LT valves / flangesCounterpart to LCB/LCC castings
CF8 / CF8MA351Cryogenic (austenitic)LNG, LIN, LOX*, cold boxesExcellent toughness at low T
CF3 / CF3MA351CryogenicWelded / low-carbon preferenceOften specified with BW ends
F316 / F316LA182CryogenicForged cryo ball / needleMatch casting/forging design

*Oxygen service needs cleaning, grease-free assembly and purchaser oxygen-compatibility rules — state “oxygen service” explicitly on the RFQ.

Temperature band quick map

Service temperature bandTypical body startEscalate when
Above −29 °CWCB / A105Corrosion needs SS
−29 to −46 °CLCB / LCC / LF2Purchaser demands stainless
Below −46 °C (e.g. LNG ≈ −162 °C)CF8M / CF3M / F316LSpecial alloys per owner spec
Liquid nitrogen / argonAustenitic SSExtended bonnet + seat notes
Liquid oxygenSS + O₂ cleaning packageOwner oxygen procedure mandatory

Cryogenic construction notes (not just MOC)

FeatureWhy it mattersWrite on RFQ
Extended bonnet / gas columnKeeps packing away from cold fluid“Cryogenic extended bonnet”
Seat materialPTFE / PCTFE / metal per tempSoft seat grade or metal seat
Stem / anti-blowoutSafety at cold operationAPI / BS cryo design notes
Body cavity reliefTrapped liquid expansionCavity relief / DIB notes if required
Low-temp seat testLeakage at MDMTTest media & temperature
Impact test / MTCProves toughnessEN 10204 3.1 + impact at MDMT

LCB vs LCC vs CF8M — short comparison

LCBLCCCF8M
FamilyLT carbon castLT carbon cast316 SS cast
CostLowerLower–midHigher
Typical MDMT−46 °C−46 °CCryogenic
CorrosionLike CSLike CSBetter chemical resistance
LNG liquidUsually noUsually noYes (with cryo design)

Screening disclaimer: MDMT values above are typical industry orientation. Final material and design temperature must follow ASME B31.3 / purchaser minimum design metal temperature, impact test exemption curves and the approved datasheet. Soft-seat temperature limits can govern before body MOC does.

RFQ fields that unblock quoting

FieldExample / why
Minimum design metal temperature (MDMT)−46 °C / −162 °C / …
MediaLNG / LIN / LOX / LT hydrocarbon
Body MOC preferenceLCC / CF8M / F316L
Valve type · size · Class · endsBall / globe / gate; BW often on cryo
Extended bonnet required?Yes / No + length if specified
Seat / soft partsPCTFE / PTFE / metal
Testing packageAPI 598 + low-temp seat test notes
Oxygen cleaning?Only if O₂ service
Quantity · deliveryCommercial offer

FAQ

Is WCB acceptable for cryogenic service?

No for true cryogenic / impact-tested low-temperature service. Use LCB/LCC or austenitic stainless (CF8M/CF3M) per design minimum temperature.

LCB or CF8M for LNG?

LNG cold boxes and liquid lines typically use austenitic stainless. LCB/LCC cover many low-temperature hydrocarbon duties around −46 °C, not full LNG liquid temperatures.

What should an RFQ include for cryogenic valves?

Minimum design temperature, media, size, Class, ends, extended bonnet requirement, seat material, testing (including low-temp seat test if specified) and quantity via contact.html.