Gas Flow Cv Calculator — Air & Process Gas Screening

Updated 2026-11-10 · Screening tool · Verify against current standards before design freeze.

Direct answer · What this calculator does

For sub-critical gas screening: Cv ≈ Q / (1360 × P1 × Y × √(x / (G×T))) simplified, or the common plant form Cv ≈ Q_scfh × √(G×T) / (1360 × P1 × √ΔP) variants. This tool uses a practical sub-critical estimate and flags high ΔP/P1 ratios.

Got a size from this tool? Send type · size · Class/PN · MOC · ends · qty.

Contact / RFQ Quote page WhatsApp

Gas inputs

SCFH
psig → psia = +14.7
psi
air = 1
°F

Results

Copy into your RFQ or open Contact / RFQ.

Formulas used

Sub-critical screening (US customary):
Cv ≈ Q / (16.05 × P1 × √(ΔP / (G × T))) when ΔP/P1 is modest
Q = SCFH, P1 = psia, ΔP = psi, G = SG (air=1), T = °R = °F+460
Critical hint: if ΔP ≥ 0.5×P1, choked flow — use full ISA/IEC gas equations
Prefer characterised globe / control or V-port ball for throttling gas. Full-bore ball for isolation with low loss.
Screening only. Not a substitute for IEC 60534 compressible sizing with expansion factor Y and xT. Confirm noise and velocity separately.

Reference table

GasSG (air=1)Notes
Air1.00Instrument / utility
N20.97Inerting
Natural gas~0.60Confirm composition
CO21.52Denser — higher Cv

How to use the result on an RFQ

  1. Run with your design data.
  2. Record the green outputs.
  3. Paste type, size, Class/PN, MOC, ends, qty into contact or WhatsApp.
  4. Request 3.1 MTC / API 598 notes when required.

FAQ

What is sub-critical gas flow?

When ΔP is small relative to absolute inlet pressure so density change across the valve is moderate.

SCFH vs Nm³/h?

Convert consistently. 1 Nm³/h ≈ 35.3 SCFH (approx, define standard conditions).

Ball or globe for gas?

Isolation: ball/gate. Throttling: globe/control or characterised ball.