Power and large captive plants mix ultra-high-pressure feedwater with low-pressure cooling water on the same BOQ. This matrix keeps the four most common contractor enquiry buckets — BFP, steam drain, CW, utility — aligned to typical valve types, Class bands and materials so RFQs stop mixing Class 150 CW butterflies with Class 1500 feedwater gates under one vague “power plant valves” line.
Master application matrix
Service
Typical valve types
Class / PN screen
MOC screen
Notes
BFP suction
Gate, butterfly, foot valve (if), strainer
150–300 / PN16–40
WCB / DI / SS
NPSH / strainer ΔP
BFP discharge isolation
Gate / parallel slide / globe
600–2500
WCB / WC6 / WC9 / F91
Per steam cycle
BFP discharge check
Swing / piston / nozzle check
Match discharge
Match line
Slam / damper
BFP recirculation / min flow
Globe / control / automatic recirculation
Match discharge
Hard trim
OEM package often
Main / HP steam
Gate, globe, check
600–2500
Alloy steels
IBR / OEM
Steam drain / drip
Gate, globe, strainer, trap
Match header
WCB / alloy
See trap chart
Blowdown
Angle BDV / tandem
Match boiler
Hard-faced
See BDV chart
CW supply / return
Butterfly, gate, knife gate
PN10/16 / 150
DI / CS / lined / seawater alloy
Large DN, actuators
CW pump discharge check
Swing / dual-plate
PN10/16
Match CW
Water hammer
Service / potable water
Gate, butterfly, ball
PN10/16
DI epoxy / brass / SS
Potable approvals if any
Instrument / plant air
Ball, needle, filter-reg
PN16 / 150
Brass / SS / CS
Oil-free if specified
Fire water
Gate OS&Y, butterfly + tamper where listed
PN16 / 150
DI / WCB
Listing if fire code
LP condensate
Gate, globe, check, ball
150 / PN16–40
WCB / CF8
Flash risk on HP drains
Chemical dosing
Diaphragm / ball / needle
Per package
Compatible alloy / lined
Corrosion Spec
BFP (boiler feed pump) detail
Location
Function
Preferred type
RFQ flags
Suction isolation
Pump take-out
Gate / butterfly
Gear on large DN
Suction strainer
Debris
Temporary / permanent basket or Y
Mesh + ΔP taps
Discharge isolation
Block
Gate / parallel slide
High Class; BW ends common
Discharge NRV
Prevent reverse
Check (type per OEM)
Slam analysis
Warm-up / bypass
Thermal
Globe small bore
Forged SW/NPT
Min-flow recirculation
Protect pump
Control / ARC valve
Often OEM skid
Drains / vents
Fill / vent
Globe / needle
Tag separately
Feedwater chemistry and oxygen scavenging can drive stainless trim even on carbon-steel bodies. State deaerator pressure, BFP shutoff head and design temperature — Class alone is not enough.
Steam drain & drip-leg train
Component
Type
Typical size
Comment
Upstream isolation
Gate OS&Y
DN15–50
Match steam Class
Strainer
Y-type SS screen
Match
80–100 mesh common
Trap
TD / bucket / F&T
Per load
See trap chart
Downstream isolation
Gate / globe
Match
Change-out
Test / drain
Globe / needle
DN15
Safe discharge
Check (if needed)
Piston / swing
Match
Return backflow
Circulating water (CW) & cooling
Duty
Valve preference
Actuation
MOC / lining
CW pump isolation
Butterfly / gate
Gear / electric
DI epoxy / CS
CW pump check
Swing / dual-plate
—
Match CW Spec
Condenser inlet / outlet
Butterfly large DN
Electric / hydraulic
Often rubber seated
Cooling tower basin
Butterfly / knife gate
Manual / electric
Corrosion Spec
Seawater CW
Butterfly / lined / alloy
As Spec
NAB / Duplex / lined DI
Auxiliary CW
Butterfly / ball / gate
Manual
DI / WCB
CW RFQs fail most often on missing torque / actuator data and missing lining Spec. Include ΔP, velocity and water chemistry.
Utility systems quick matrix
Utility
Common valves
Class screen
Ends
Plant / instrument air
Ball, needle, filter
150 / PN16
NPT / SW / RF
Nitrogen / inert
Ball, globe
150–300
SW / RF
Demin / condensate polish
Butterfly, diaphragm, ball
PN10/16
RF / wafer
Fuel oil (light)
Ball, gate, globe
150–300
RF / SW; fire-safe if Spec
Fire water
OS&Y gate, listed butterfly
PN16 / 150
RF / grooved if Spec
Drainage / effluent
Knife gate, butterfly, ball
PN10
Wafer / RF
Operation & actuation screening
Size / duty
Manual
Gear
Actuated
≤DN50 low Class
Handwheel / lever
Rare
If remote
DN65–200
Handwheel
Often
If ESD / remote
≥DN250 CW / large steam
—
Common
Electric / pneumatic / hydraulic
High-Class HP feedwater
Gear even on mid sizes
Yes
Motor on critical isolation
Documentation package by service band
Band
Typical docs
HP steam / BFP discharge
3.1 MTC, GA, hydro chart, IBR if applicable, PMI if Spec
3.1 or 2.2 per purchaser; hydro per API 598 / EN 12266
FAQ
What valve types are typical on BFP suction and discharge?
Boiler feed pump (BFP) suction often uses large gate or butterfly isolation with suction strainer; discharge uses high-Class gate/globe isolation, non-return (check) valves, and recirculation/minimum-flow control valves per OEM. Ratings follow feedwater design pressure — commonly Class 600–2500 depending on plant steam conditions.
Which valves are used on steam drain lines?
Steam drain and drip legs typically use gate or globe isolation, Y-strainers, steam traps, and sometimes dual isolation with a drain globe. Class and MOC follow the steam header; see the IBR steam rating and steam trap charts.
What is common for circulating water (CW) valves?
CW and cooling-water systems use large butterfly (often rubber-lined or metal-seated), knife gate or gate valves, with DI/CS/epoxy or seawater alloys as specified. Pressure is usually low (PN10/PN16 / Class 150) but sizes are large — torque and actuator duty dominate the RFQ.
Are utility valves the same Class as main steam?
No. Instrument air, service water, fire water and LP condensate utilities are usually Class 150 / PN16 or lower. Always take Class from the line list, not from the nearest main-steam Class.
What should a power-plant valve RFQ include?
Tag, service (BFP/steam drain/CW/utility), size, Class/PN, MOC, ends, operation (manual/gear/actuator), design P/T, fluid, IBR if steam, test standard, quantity and any NACE/coating notes.
Application screening for 2026 EPC and plant enquiries. Freeze selections on the purchaser line list, OEM manuals and current ASME / API / IBR editions.