Flange Bolt Torque Chart (Typical Values by Size & Class)

Updated 2026-11-08 · Orientation / screening only — not a site procedure.

Direct answer · Flange bolt torque

Torque depends on stud grade, lubricant, gasket type, flange class and target bolt stress. The tables below give typical lubricated orientation values for common ASME B16.5 RF joints so contractors can sense-check a procedure — they are not IFC torque without project-specific calculation.
Strong disclaimer: Do not use this page as the sole source for hydrotest or in-service flange assembly. Over-torque crushes gaskets and warps flanges; under-torque leaks. Freeze torque on the EPC bolting procedure, gasket maker data sheet, and calibrated tools. Supreme Valves does not certify field bolting from this chart.

Need flanged valves for a bolting package? Send size · class · facing · MOC · qty.

Contact / RFQ WhatsApp

Assumptions for the orientation tables: ASTM A193 B7 studs / A194 2H nuts, lubricated threads (typical nut factor K ≈ 0.15–0.18), spiral-wound or CAF-style RF gasket, ambient assembly. Change any of those and the torque changes. For interactive sizing see the flange bolt torque calculator.

Typical lubricated torque by bolt size (orientation)

Bolt / stud sizeTypical target stress bandLubricated torque (N·m)Lubricated torque (ft·lb)Notes
½"Screening60–9045–65Common Class 150 small bore
⅝"Screening120–17090–125Class 150 / 300 mid sizes
¾"Screening200–280150–205Watch gasket crush on soft CAF
⅞"Screening320–420235–310Class 300 / 600 common
1"Screening480–620355–455Use calibrated hydraulic / torque tools
1⅛"Screening680–860500–635Multi-pass star pattern mandatory
1¼"Screening900–1150665–850Often tensioner preferred on critical lines
1½"Screening1600–20001180–1475Confirm with project procedure

Class 150 RF — bolt count & orientation torque band

NPSBolts × sizeTypical lubricated band (N·m)Pass sequence cue
2"4 × ⅝"120–17030% → 60% → 100% star
3"4 × ⅝"120–17030% → 60% → 100% star
4"8 × ⅝"120–170Cross pattern; circular finish
6"8 × ¾"200–280Cross pattern; circular finish
8"8 × ¾"200–280Cross pattern; circular finish
10"12 × ⅞"320–420Numbered star; 4 passes typical
12"12 × ⅞"320–420Numbered star; 4 passes typical
16"16 × 1"480–620Consider tensioners on critical service
20"20 × 1⅛"680–860Project procedure governs
24"20 × 1¼"900–1150Project procedure governs

Class 300 / 600 RF — bolt size jumps (screening)

NPSClass 300 boltsClass 600 boltsTorque cue
4"8 × ¾"8 × ⅞"Class 600 needs higher band — do not reuse Class 150 torque
6"12 × ¾"12 × 1"Bolt diameter jump drives torque up sharply
8"12 × ⅞"12 × 1⅛"Verify lubricant and gasket crush load
10"16 × 1"16 × 1¼"Hydraulic torque / tensioner common
12"16 × 1⅛"20 × 1¼"More bolts + larger size on Class 600
16"20 × 1¼"20 × 1½"Always use purchaser bolting procedure

What changes the number

VariableEffect on wrench torqueRFQ / site note
Dry vs lubricatedDry often ~25–40% higher for same tensionState paste / moly / dry in procedure
B8 / B8M stainless studsLower usable stress; galling riskDo not copy B7 torque blindly
Soft CAF / PTFE gasketLower seating stress neededEasy to crush — lower end of band
Spiral wound / RTJHigher seating / ring engagementFollow gasket / ring maker data
Hot re-torqueMay be specified after heat-upOnly if procedure allows

Screening data only. Confirm bolt counts against Class 150/300 and Class 600 dimension charts and the current ASME B16.5 edition.

FAQ

Can I use this flange bolt torque chart for final field torque?

No. These are orientation / screening values only. Final torque must come from the project bolting procedure, gasket manufacturer data, lubricant, and stud grade.

Do lubricated and dry studs use the same torque?

No. Dry threads need significantly higher wrench torque to reach the same bolt stress. Always state lubricant (or dry) in the procedure.

Does Supreme Valves set field bolting torque?

Supreme Valves supplies flanged valves. Field flange assembly torque is set by the piping contractor / EPC bolting procedure, not by the valve datasheet alone.