Updated 2026-11-21 · Supreme Valves India · Ahmedabad
A fully open gate valve has a straight, almost unobstructed bore, so its flow coefficient is high and its pressure drop is small. The Cv value matters when you add up line losses, not for control: a gate valve is an isolation valve and should not be used part-open.
Quick answer
Calculated Cv for a fully open gate valve: 1" ≈ 76.7, 2" ≈ 328, 4" ≈ 1,310. Cv is the flow of water in US gallons per minute that gives a 1 psi pressure drop. These are calculated estimates; use the manufacturer's datasheet value for final sizing.
Gate Valve Cv and Kv table (DN15 to DN600)
Size (NPS)
DN
Bore used (in)
K
Cv
Kv
½"
DN15
0.622
0.216
24.9
21.5
¾"
DN20
0.824
0.200
45.4
39.3
1"
DN25
1.049
0.184
76.7
66.3
1¼"
DN32
1.380
0.176
136
117
1½"
DN40
1.610
0.168
189
164
2"
DN50
2.067
0.152
328
283
2½"
DN65
2.469
0.144
480
415
3"
DN80
3.068
0.144
742
642
4"
DN100
4.026
0.136
1,310
1,140
5"
DN125
5.047
0.128
2,130
1,840
6"
DN150
6.065
0.120
3,170
2,750
8"
DN200
7.981
0.112
5,690
4,920
10"
DN250
10.020
0.112
8,970
7,760
12"
DN300
11.938
0.104
13,200
11,400
14"
DN350
13.124
0.104
16,000
13,800
16"
DN400
15.000
0.104
20,900
18,000
18"
DN450
16.876
0.096
27,500
23,800
20"
DN500
18.812
0.096
34,200
29,500
24"
DN600
22.624
0.096
49,400
42,700
Basis: K = 8 × fT for a full-bore wedge gate valve, fully open, with the Crane TP-410 friction factor fT for each size and the Schedule 40 pipe inside diameter as the bore. Values are rounded to three significant figures. Tested values on a manufacturer's datasheet are usually lower, because seat rings, port shape and body geometry add resistance.
K is the resistance coefficient of the fully open valve. Crane Technical Paper 410 expresses it as a multiple of the pipe friction factor fT, which lets one formula cover every size. If you know the actual seat bore of the valve you are buying, put that diameter into the formula instead of the Schedule 40 figure.
Pressure drop through a gate valve
ΔP (psi) = SG × (Q ÷ Cv)² (Q in US gpm)
ΔP (bar) = SG × (Q ÷ Kv)² (Q in m³/h)
Example: water (SG 1.0) at 400 US gpm through a 4" gate valve with Cv 1,310 gives ΔP = (400 ÷ 1,310)² ≈ 0.09 psi. In metric units, 90 m³/h through the same valve (Kv 1,140) gives about 0.006 bar.
Pressure-drop and required-Cv calculator (liquids)
What changes the Cv of a real gate valve
Pressure class. Higher classes have thicker walls and, in some designs, a smaller seat bore. A Class 600 valve can have a lower Cv than a Class 150 valve of the same nominal size. Use the actual seat bore if you have it.
Reduced (venturi) port. Forged API 602 gate valves are commonly supplied with a reduced port, and their Cv is well below the full-bore figure. Ask for the datasheet value.
Throttling. The table is for a fully open valve only. A part-open gate valve has an unstable, non-linear characteristic, and the high velocity under the wedge erodes the seats. Use a globe or control valve where flow has to be regulated.
Slab and through-conduit gates. A through-conduit gate valve presents a smooth full bore and behaves close to a piece of pipe, so its Cv is at or above the wedge-gate figure.
Send line size, class, fluid, flow and allowable pressure drop. We reply with a matched gate valve offer and datasheet.
Calculated for a full-bore valve, fully open, a 2 inch (DN50) gate valve has a Cv of about 328 (Kv about 283). Catalogue values for a specific make are often lower, so use the manufacturer's figure for final calculations.
How do I calculate pressure drop across a gate valve?
For liquids, pressure drop in psi = SG × (Q ÷ Cv)², with Q in US gallons per minute. In metric units, pressure drop in bar = SG × (Q ÷ Kv)², with Q in m³/h.
Can a gate valve be used for throttling?
No. A gate valve is designed to be fully open or fully closed. Part-open operation causes vibration and seat erosion. Use a globe valve or a control valve to regulate flow.
Why is gate valve Cv higher than globe valve Cv?
Flow passes straight through a gate valve, while a globe valve turns the flow through the seat. The resistance coefficient of a standard globe valve is about 40 times that of a gate valve, so its Cv is roughly one sixth for the same size.
Reference: Crane Co., Technical Paper No. 410, Flow of Fluids Through Valves, Fittings and Pipe. This page is an engineering aid, not a substitute for the valve manufacturer's tested flow data.