Download PDF
Supreme Valves India Logo

Supreme Valves India

Ranginwala Building, Relief Road, Ahmedabad 380001, Gujarat, India
Tel: +91 97732 78770 | Email: supremevalvesindia@gmail.com | www.supremevalves.in

Manifold Valve -- 2-Way / 3-Way / 5-Way Instrument

Technical Datasheet -- Integral Instrument Manifold Valves for Transmitter Isolation

Document No.SV-DATA-MNV-001
RevisionA
DateMay 2026
ManufacturerSupreme Valves India, Ahmedabad, Gujarat, India

Instrument manifold valves for pressure, differential pressure, and level transmitter isolation, equalisation, and venting. Integral multiple needle or ball valves machined from a single SS316 or duplex stainless steel barstock forging. 2-way (direct mount isolator), 3-way (equalising), and 5-way (differential pressure transmitter manifold) configurations. NACE MR0175 sour service standard. Compact direct-mount design eliminates tubing and brackets. Colour-coded handles by function. API 602 / ASME B16.34 / NACE MR0175 compliant.

Technical Specifications
ParameterSpecification
Product TypeInstrument Manifold Valves
CategoryMulti-Port Valves
Size Range1/4" to 1/2" (DN8 to DN15) -- process connection: 1/2" NPT female typical; instrument connection: 1/4" or 1/2" NPT female typical
Pressure RatingUp to 10,000 psi (689 bar) -- standard: 6,000 psi (414 bar)
Process ConnectionThreaded NPT / BSP / metric (1/2" typical), Flanged RF (small size), Socket weld, Butt weld, Tube fitting compression (1/4" to 1/2" OD)
Instrument ConnectionThreaded NPT / BSP / metric (1/4" or 1/2" typical), Tube fitting compression (1/4" to 1/2" OD)
Body MaterialASTM A182 F316 (SS316 forged barstock) / ASTM A105 (carbon steel forged barstock) / ASTM B564 UNS N04400 (Monel) / Duplex SS ASTM A182 F51 / F53
Valve TrimSS316 precision needle with Stellite 6 tip (needle valves) / SS316 ball with ENP or chrome plating (ball valves) / PTFE/RPTFE or graphite packing
Seat MaterialSS316 integral seat with Stellite 6 overlay (needle) / PTFE/RPTFE seat (ball)
Configuration2-way: 1 process + 1 instrument (direct mount isolator) / 3-way: 1 process + 2 instruments or 1 process + 1 instrument + 1 vent (equalising) / 5-way: 2 process (H/L) + 2 instrument + 1 vent (differential pressure transmitter manifold)
Leakage ClassAPI 598 / EN 12266-1 Class A -- zero visible leakage for all needle and ball valves at rated pressure
Temperature Range-50 deg C to +200 deg C (PTFE packing) -- up to +540 deg C (graphite packing, SS316 body)
Materials of Construction
ComponentMaterial
Stainless SteelASTM A182 F316 (SS316) forged barstock body, needle, ball, and seat (standard instrument service)
Carbon SteelASTM A105 forged barstock body (standard industrial, non-corrosive)
Nickel AlloyASTM B564 UNS N04400 (Monel) body and trim (seawater / reducing acid service)
Duplex Stainless SteelASTM A182 F51 / F53 (duplex SS) body and trim (sour gas / chloride service per NACE MR0175)
Testing & Inspection
TestRequirement
TestingHydrostatic shell test 1.5 x WP per API 598 / EN 12266-1; Seat leakage test per API 598 / EN 12266-1; Functional test -- full stroke, torque; Material certificates per EN 10204 3.1
CertificationISO 9001:2015 QMS, EN 10204 3.1 material certificates, hydrostatic and seat test reports
Applicable Standards
StandardDescription
Design StandardAPI 602 Compact Steel Gate/Globe/Check Valves, ASME B16.34, NACE MR0175 (standard for sour service)

Notes