2-Valve Instrument Manifold -- Block & Bleed SS316
Compact Direct-Mount Instrument Manifold for DP Transmitters and Gauges
Document No.SV-DS-MNF-001
RevisionRev A
DateMay 2026
ManufacturerSupreme Valves India, Ahmedabad, Gujarat, India
This datasheet covers compact 2-valve instrument manifolds machined from solid SS316 barstock with integral block and bleed needle valves for direct mounting to differential pressure transmitters, gauges, and level instruments.
Technical Specifications
| Parameter | Specification |
| Size Range | 1/2" NPT process x 1/2" NPT instrument (standard) |
| Pressure Rating | 6,000 PSI (standard), 10,000 PSI (high-pressure option) |
| Body Material | Solid SS316 barstock, one-piece machined |
| Valve Type | Block and bleed needle valves |
| Needle Tip | SS316 non-rotating Vee-point tip |
| Seat Material | Integral SS316, matched-lapped |
| Temperature Range | -73°C to +538°C (graphite packing) |
| Connections | 1/2" NPT male/female process; 1/2" NPT female instrument |
| Mounting | Direct mount 54 mm centre-to-centre for most DP transmitters |
| Handle | SS304 knurled handwheel standard; T-bar optional |
| Features | Integral block and bleed, non-rotating tip, blow-out proof stem, panel mountable |
Materials of Construction
| Component | Material |
| Body | SS316 solid barstock, one-piece machined, 100% volumetric ultrasonic tested |
| Needle | SS316 hardened non-rotating Vee-point tip, matched-lapped to integral seat |
| Stem | SS316 anti-blow-out stem with ACME threads and thrust collar |
| Packing | PTFE V-rings (standard) or graphite braided (high temperature) |
| Gland Nut | SS316 hex gland nut with smooth threads to prevent galling |
| Bonnet | SS316 threaded or union bonnet for in-line packing replacement |
| Handle | SS304 knurled handwheel standard; T-bar for high-torque service |
Testing & Inspection
| Test | Requirement |
| Test Standard | Hydrostatic 1.5x rated pressure per API 598 / MSS SP-99 |
| Certification | CE, ISO 9001, NACE MR0175 on request |
Applicable Standards
| Standard | Description |
| Design Standard | ASME B16.34 / MSS SP-99 |
Notes
- Manifold centre-to-centre dimension must match transmitter bolt pattern; standard 54 mm suits most common DP heads.
- Non-rotating tip is standard; specify rotating tip only if media contains abrasive particles requiring self-cleaning action.
- For sour gas service (H2S > 0.01 MPa partial pressure), select NACE MR0175 compliant material with hardness < 22 HRC.
- Panel-mount version includes square body and lock nut; specify panel thickness for correct nut thread length.
- Manifold must be depressurised before operating bleed valve; open bleed slowly with downstream isolated.