Sanitary Butterfly Valve -- Tri-Clamp SS316L 3A Dairy
Hygienic CIP/SIP Compatible Process Valve for Dairy, Beverage, and Pharma
Document No.SV-DS-SPC-002
RevisionRev A
DateMay 2026
ManufacturerSupreme Valves India, Ahmedabad, Gujarat, India
This datasheet describes tri-clamp sanitary butterfly valves in SS316L with FDA-compliant EPDM liner for dairy, beverage, pharmaceutical, and biotech process lines requiring 3A and EHEDG hygienic compliance.
Technical Specifications
| Parameter | Specification |
| Valve Size Range | DN25 to DN200 (1" to 8") Tri-Clamp |
| Pressure Rating | PN10 (vacuum to 10 bar) |
| Body Material | Forged SS316L (1.4404), Ra 0.8 µm internal finish |
| Disc Material | SS316L, polished Ra 0.8 µm, no crevices or threads exposed to product |
| Seat Material | FDA 21 CFR 177.2600 EPDM, white, steam-resistant to 135°C |
| Liner Retention | Stainless steel retainer ring with tri-clamp gasket capture |
| Temperature Range | -10°C to +135°C (CIP/SIP cycles) |
| End Connections | Tri-Clamp (TC) per DIN 32676 / SMS / ISO 2852 |
| Surface Finish | Internal Ra 0.8 µm, external Ra 1.6 µm |
| CIP/SIP | Full CIP ball and SIP steam compatibility; no dead legs |
| Actuation | Manual locking lever, stainless steel handle, pneumatic or electric on request |
Materials of Construction
| Component | Material |
| Body | SS316L forged, fully machined, no casting porosity, Ra 0.8 µm ID |
| Disc | SS316L solid disc, polished to Ra 0.8 µm, seamless seal contact surface |
| Seat / Liner | White FDA EPDM, bonded to retainer ring, replaceable without removing valve from line |
| Shaft | SS316L, ground and polished, sealed by EPDM liner, no exposed threads |
| Retainer Ring | SS316L split ring with tri-clamp ferrule; captures liner and provides seal |
| Handle | SS304 four-position locking lever with SS316 pin and spring |
| Gaskets | PTFE-encapsulated silicone tri-clamp gaskets supplied with valve |
Testing & Inspection
| Test | Requirement |
| Test Standard | Hydrostatic 1.5x PN, vacuum 0.8 bar without collapse |
| Certification | FDA, 3A, EHEDG, CE, ISO 9001 |
Applicable Standards
| Standard | Description |
| Design Standard | 3A Sanitary Standard 54-02 / EHEDG guidelines |
Notes
- All product-contact surfaces are finished to Ra 0.8 µm and pass 100% boroscope inspection before dispatch.
- FDA EPDM liner is white for visual contamination detection; black NBR or PTFE-lined options available for non-food service.
- Tri-clamp ferrule size must match existing line ferrules (DIN 32676, SMS, or ISO 2852); specify at order.
- For SIP service above 135°C, specify PTFE or platinum-cured silicone liner with high-temperature handle.
- Valves are supplied bagged in polyethylene with nitrogen purge; store in original packaging until installation.