Direct answer · Updated 25 October 2026

Where can I get FM approved and UL listed valves from India, and how do I check the listing?

Supreme Valves India (Ahmedabad) supplies UL Listed and FM Approved fire protection valves: resilient wedge OS&Y and NRS gate valves, butterfly valves with supervisory tamper switch, resilient swing check valves, dual plate wafer check valves and Y-strainers, 2" to 24", PN16, flanged or grooved. Verify any valve by looking up its exact model in the FM Approval Guide and the UL Product iQ directory; we state the listing reference for each model and size on the offer.

Request a quotation · +91 97732 78770 · info@supremevalves.in

UL ListedFM ApprovedNFPA 13 / 20 / 24PN16 · 2"–24"

UL Listed & FM Approved Valves — Supplier in India

Listed fire-water valves for sprinkler, hydrant, fire pump and deluge systems, supplied with listing references, datasheets and test certificates for consultant and civil defence approval.

Request Enquiry WhatsApp Engineering

UL Listed vs FM Approved: what each mark means

A UL Listed valve has been tested by Underwriters Laboratories against a UL standard for fire service (for example UL 262 for gate valves, UL 1091 for butterfly valves, UL 312 for check valves) and the factory is under UL follow-up inspection. Each listing sits under a UL file number that can be looked up in the UL Product iQ directory.

An FM Approved valve has been tested by FM Approvals (FM Global group) against an FM approval standard (for example Class 1120/1130 for gate valves, Class 1112 for butterfly valves, Class 1210 for check valves) and appears in the FM Approval Guide. FM approval is usually required where the property is insured by FM Global or the specification calls for FM.

Many fire-water specifications ask for UL/FM, meaning the exact model and size must appear in both listings. LPCB (UK) and VdS (Germany) are equivalent third-party approvals used in Europe, the Gulf and some Asian projects.

ItemUL ListedFM Approved
BodyUnderwriters LaboratoriesFM Approvals (FM Global)
DirectoryUL Product iQ (file number EX....)FM Approval Guide
Typical valve standardsUL 262, UL 1091, UL 312FM Class 1120/1130, 1112, 1210
Common demandNFPA 13 / 14 / 20 / 24 systems, consultants, civil defenceFM Global insured sites, oil & gas, warehouses
Marking on valveUL mark + modelFM diamond mark + model

How to verify an FM approval or UL listing before you order

Supreme Valves supplies UL Listed and FM Approved constructions from listed manufacturing plants. Each offer states the listing reference for the model and size quoted, so the consultant or civil defence reviewer can verify it independently.

UL / FM approved constructions available

Standard listed fire-water constructions (ductile iron body EN-GJS-450-10, EPDM resilient seating, stainless steel stem, fusion bonded epoxy coating to AWWA C550, rated PN16 at 0–100°C). Listing scope differs per construction; we confirm the exact approval for each size on the quotation.

ConstructionApprovalSizesEnds
Resilient wedge OS&Y gate valve, flanged (BS 5163 pattern)UL Listed / FM Approved2" – 24"Flanged BS EN 1092-2 PN16
Resilient wedge OS&Y gate valve, groovedUL Listed / FM Approved2" – 12"Grooved ISO 6182
Resilient wedge NRS gate valve, flangedUL Listed / FM Approved2" – 24"Flanged BS EN 1092-2 PN16
Resilient wedge NRS gate valve with post-indicator flangeUL Listed / FM Approved4" – 16"Flanged BS EN 1092-2 PN16
Resilient wedge NRS gate valve, groovedUL Listed / FM Approved2" – 12"Grooved ISO 6182
Wafer butterfly valve with supervisory tamper switchUL / FM / VdS2" – 12"Wafer, PN16 flanges
Lugged wafer butterfly valve with tamper switchUL / FM / VdS2" – 12"Lug, PN16 flanges
Grooved butterfly valve with tamper switchUL / FM / VdS2" – 12"Grooved ISO 6182
Resilient seated swing check valve, flangedUL Listed / FM Approved2" – 12"Flanged BS EN 1092-2 PN16
Resilient seated swing check valve, groovedUL / FM / LPCB2" – 12"Grooved ISO 6182
Double door (dual plate) wafer check valveUL Listed2" – 16"Wafer, PN10/PN16, AS 2129
Y-type strainer, flangedUL Listed2" – 24"Flanged BS EN 1092-2 PN16
Y-type strainer, groovedUL Listed2" – 12"Grooved ISO 6182

Where UL / FM valves are used

Sprinkler riser control valves, fire pump suction and discharge isolation (NFPA 20), hydrant ring mains and underground fire mains (NFPA 24), standpipe systems (NFPA 14), deluge and foam skids, and fire-water networks in refineries, tank farms, warehouses, data centres, malls and high-rise buildings. We supply projects in India and export to the UAE, Saudi Arabia, Kuwait, Qatar, Oman and Africa where civil defence approval requires UL or FM listed equipment.

What to send with your enquiry

Send the line list or datasheet to info@supremevalves.in or use the quote builder. Technical clarifications and a priced offer follow within one working day for standard items.

Related products and guides

Fire protection valves hub

Full range of fire-water valves and accessories.

UL / FM OS&Y gate valve

Rising stem gate valve for sprinkler and pump isolation.

UL / FM wafer butterfly valve

Butterfly valve with supervisory tamper switch.

UL / FM swing check valve

Resilient seated check valve for fire pump discharge.

UL / FM alarm valve

Wet riser alarm check assembly.

UL / FM deluge valve

Deluge valve for water spray and foam systems.

UL / FM certified valve guide

Detailed guide to fire protection valve certification.

Fire protection valves for Kuwait

Gulf export and civil defence documentation.

Frequently asked questions

What is the difference between UL listed and FM approved valves?

UL listing is issued by Underwriters Laboratories against UL standards such as UL 262 and UL 1091; FM approval is issued by FM Approvals against FM classes such as 1120 and 1112. Both involve type testing and factory audits. Many specifications require both (UL/FM) for the same model and size.

How do I check if a valve is FM approved?

Search the exact model in the FM Approval Guide (approvalguide.com). The entry lists the manufacturer, model, sizes, end connections and rated working pressure. For UL, search the UL Product iQ directory using the UL file number.

Do you supply UL / FM valves with certificates?

Yes. The offer states the listing reference for each model and size, and we supply the datasheet, listing certificate pages and hydrostatic test certificates with the material.

What sizes and pressure ratings are available?

Standard listed constructions cover 2" to 24" at PN16 (approximately 232 psi), with flanged BS EN 1092-2 or grooved ISO 6182 ends. Other ratings such as 250 psi and 300 psi are quoted on request depending on the listing.

Is a UL listed gate valve also FM approved?

Not automatically. The model and size must appear in both directories. Several resilient wedge OS&Y and NRS gate valves we supply carry both UL and FM approval; we confirm it per size on the quotation.

Do you export UL / FM valves to the Middle East?

Yes. We supply UL / FM fire protection valves to the UAE, Saudi Arabia, Kuwait, Qatar and Oman with the documentation needed for consultant and civil defence approval.

About this page: Written by the Supreme Valves India engineering team, Ahmedabad (supplying industrial valves since 1986). Last reviewed 25 October 2026. Figures are typical values for selection; the governing values are those in the referenced standard and on the approved datasheet for each order. Entity facts: Supreme Valves brand facts.

Need UL / FM listed valves for a fire-water project?

Send size, pressure rating, material, end connection and service. Engineering response within one working day.

Configure RFQ Contact Engineering